Check the thermostat fan setting first: if it is on On instead of Auto, the furnace blows room-temperature air between heating cycles. Next check a dirty filter, then pilot, igniter and flame sensor problems that keep the burners from lighting.
A home heating system should keep the temperature steady and provide a consistent source of heat.
If you have ever looked forward to shedding layers of clothing as soon as you get home from work, only to experience cold air blowing out of your heater vents, you know how frustrating a broken heater can be.
Unfortunately, it’s not uncommon for heaters to fail from time to time.
There are many do-it-yourself steps you can take before calling a repairman. By knowing what part of your heating system may need attention, you can save money and avoid sending an HVAC technician on a wild goose chase with your broken heater.
7 Possible Causes For Your Furnace Blowing Cold Air

Issue #1: The Blower Wheel
The blower wheel is one possible cause of weak airflow from your vents.
It is located at the bottom or rear of the unit and sits inside a metal housing. When you turn on your heating system, the blower wheel spins to pull air from inside your home and push it through the vent openings throughout your property.
If this component becomes worn or cracked, there will be less airflow coming out of your vents, resulting in colder rooms that take longer to heat up.
Replacing this part can be very easy if you have experience with small appliances and tools.
But, make sure you withhold judgment until after checking all other components for failure before assuming anything about your blower wheel.
Issue #2: The Thermostat
The thermostat is responsible for controlling the heat of your home and telling your heater when to turn on and off as you make adjustments to room temperature. This component begins working as soon as you fire up your heater.
The most common thermostat mistake is a fan setting switched to On instead of Auto. With the fan on, the blower runs between heating cycles and pushes out room-temperature air. Switch it to Auto. Also, some furnaces delay the blower for a minute or two so the heat exchanger can warm up, so a short burst of cool air at startup is normal.
If the fan is on Auto and your thermostat is set to heat, but the furnace is still blowing cold air after several minutes, the thermostat may be failing or the burners may not be lighting. If the burners never light, our furnace won’t turn on checklist walks through the checks in order.
To check if your thermostat needs attention, manually adjust the settings on it with nothing else powered on in your house.
You should see a change in temperature almost immediately.
If this isn’t the case, the part should be checked over by an HVAC technician to ensure it is working properly.
Get matched with a local HVAC technician
Networx matches you with vetted pros near you. Free, no obligation.
Issue #3: The Filter
If you notice your heater running for extended periods of time while making no noticeable difference in the temperature of your home, your filter may need to be changed. Heater filters trap dust and other contaminants that might otherwise flow through ducts and vents into your living space.
A dirty filter restricts airflow, so heat builds up and a high-limit switch can shut off the burners while the blower keeps running, which blows unheated air. You should check the filter every month during regular maintenance inspections for optimal heater function.
ENERGY STAR says to inspect, clean or change your filter once a month during heating season.
Issue #4: The Heat Exchanger
The heat exchanger is the metal chamber that passes heat from the burners to the air your blower sends through the ducts.
If this part is dirty or damaged, the furnace can shut down and push cold air out of your vents. A damaged heat exchanger is also a safety problem: CPSC warns that fuel-burning heating systems can cause carbon monoxide poisoning if they are poorly maintained.
This can quite often be confused with a clogged filter or blower wheel, but if you notice decreased airflow coming from vents and no noticeable change in temperature, the heat exchanger may need attention.
Replacing this component is a job for a professional, because of its location inside the furnace and the carbon monoxide risk.
Issue #5: The Circuit Board
A faulty circuit board can create a number of problems for your heater and blower wheel, preventing them from working together to warm up your home.
If you notice that no matter how long your unit runs, there is no change in temperature or airflow, this component may be the culprit. Many furnaces flash a diagnostic code on the control board that your manual explains, so check it before you call. Our Carrier, Goodman, Lennox and Trane code lists decode the flashes. Board repairs are a job for a technician.
However, if you have tried all other items on the list and still aren’t receiving any heat from your heating unit, replacing the circuit board might be necessary.
Issue #6: Condensate Drainage
If you are noticing cold air coming out of vents even after running your system for several minutes or if water is collecting in your unit’s base pan, you may have a condensate drainage issue.
This could be caused by a clogged drain line or loose tubing. Condensate lines are found on high-efficiency furnaces. Check that the drain line and its trap are connected and not blocked.
If you do not see an obvious clog, call a technician: Carrier lists faulty condensate lines among the more complex causes.
Issue #7: The Thermocouple
Still trying to figure out why your furnace is blowing cold air? In a furnace with a standing pilot light, the thermocouple senses the pilot flame. Newer furnaces use an electronic igniter and a flame sensor instead, and a dirty flame sensor can stop the burners from staying lit.
If the pilot goes out or the sensor cannot detect the flame, the burners will not light, and the fan will keep blowing unheated air. If your pilot has gone out, see how to light a furnace pilot light.
Gas components are a job for a qualified professional. If you smell gas, leave the home and contact your gas utility or emergency services.
In Conclusion
If the furnace is still blowing cold air after checking all of the above components, it may be time to call in a professional. If your furnace burns oil, check the tank first: see what to do when you run out of heating oil.
A professional HVAC technician will inspect every part of your heater and determine what parts need attention. If you notice that some components are worn or damaged, it may be time to replace them entirely for more efficient heating later on down the road.
You can avoid this fate by scheduling a tune-up with a licensed HVAC contractor once a year, in the fall before the coldest months hit.
This will ensure every component in your heater is working properly and maximize warmth when you need it most.